Project Description

- Very low output ripple and spikes
- EMC surpasses CE requirements: low emission & high immunity
- Excellent dynamic response to load changes
- Protected against all overload and short circuit conditions
- Designed for long life at full power
- Master / Slave parallel and series operation with voltage and current sharing
- Voltage and current control with 10 turn potentiometers
- For laboratory use or optional 19” rack mounting
- Convection cooling
Single phase input | 90-265 V AC (48-62 Hz) |
Active Power Factor Correction (PFC) | 0.99 / 0.83 (at 100% load) |
Efficiency | up to 84% (at full load) |
Output ripple and spikes | from 0.5 mVrms / 8 mVpp |
Regulation | from 5 mV (0-100% load step) |
Recovery time | from 100 μs (50-100% load step) |
Programming speed | from 7 ms (10-90%) |
Analog programming accuracy | from 0.2% |
Output voltage and current stability | 10.10-5 / 10.10-5 |
MTBF | 500.000 hrs |
Operating ambient temperature | -20 to +50 °C |
Power supply standard | EN 61204-3 |
Generic Emission | EN 61000-6-3 (EN 55022B) |
Generic Immunity | EN 61000-6-2 |
Safety | EN 60950 / EN 61010 |
Insulation input / output | 3750 Vrms |
Enclosure | IP20 |
Width = ½ 19
Height = 66 mm (incl. feet)
Depth = 202 mm
Weight = 1.7 kg

Partnumber | Voltage range | Current range |
---|---|---|
ES 015-10 | 0 – 15 V | 0 – 10 A |
ES 030-5 | 0 – 30 V | 0 – 5 A |
ES 075-2 | 0 – 75 V | 0 – 2 A |
ES 0300-0.45 | 0 – 300 V | 0 – 0.45 A |
![]() |
Increased Output Power | |
---|---|---|
The conservatively rated unit allows todeliver extra output power with the same reliability. At some derating,either the maximum output voltage or the maximum output current can be increased by about 10%. | ||
![]() |
High Voltage Isolation (up to 1000 V) | |
A higher output isolation allows series operation up to1000 V. | ||
![]() |
Sequencer | |
Arbitrary Waveform generator or standalone automation. The sequencer is integrated in the Ethernet controller. | ||
![]() |
19 Inch Rack Mounting Adapter | |
Using the 19 inch mountingadapters, it is possible to position the ES units in a 19 inch rack. Several configurations possible with multiple ES and / or PSC or ISO AMP modules. |
||
![]() |
Rear Power Output and Remote Sensing | |
Output terminals at the rear panel instead of bind posts at the front panel, includes remote sensing. | ||
![]() |
Secured Voltage and Current Setting | |
For maximum security, the CV / CC settings can be adjusted with a screwdriver only and are protected with a plastic cap from accidental adjusting. | ||
![]() |
Software Control and Interfaces | |
Factory installed programming interfaces:
|
External programming interface modules:
|
Downloads | Document format | Size |
---|---|---|
Data sheet ES150-Series | PDF (Acrobat Reader) | 384.0 KB |
Data sheet Ethernet interface | PDF (Acrobat Reader) | 73.6 KB |
Data sheet IEEE488 & RS232 interface | PDF (Acrobat Reader) | 153.7 KB |
Data sheet ISO AMP option SM-Series | PDF (Acrobat Reader) | 86.5 KB |
Data sheet PROFIBUS & CANopen interface | PDF (Acrobat Reader) | 129.6 KB |