Vicor Corporation designs, manufactures and markets modular power components and complete configurable and custom power systems. These are primarily used by OEMs in the communications technology, data processing, control technology, test and measurement instruments, medical technology, aviation and defense technology industries. Below you will find the product overview for industrial applications.

Product overview AC-DC
Image
Description
Datasheet
Input
Output
Power
- Small size, low profile
- Simplifies thermal design
- Integrated filtering, transient protection, inrush protection
- High efficiency of up to 92%
85.0 - 264.024.0 / 48.0400.0- Isolated AC-DC converter with Power Factor Correction (PFC)
- Integrated solution streamlines design, reduces time to marketIntegrated solution streamlines design, reduces time to market
- Low-profile, 9.55mm height above board
- 48V isolation and regulated output with safe, low-voltage energy storage
85-26448330
Image
Description
Datasheet
Input
Output Power
Efficiency
- Universal input 85 – 264VAC
- Integral EMI filtering
- Input transient protection
- Inrush limiting
85 – 26425097%- AC front-end module for 300VIN DC-DC converters
- Autoranging line rectification
- Inrush current limiting
- Quarter-brick package
90 – 132 / 180 – 264 / 115V / 230V500/ 750/ 150096 – 98%- Autoranging 115/230VAC input
- Harmonic current attenuation to EN61000‑3‑2
- EMI filtering to EN55022, Level B (with recommended filter)
- Transient immunity to EN61000-4-5
115/23057597%- EMI filtering
- Autoranging line rectification
- Inrush current limiting
- Half-brick package
115/230500/750 or 750/100096%- 0.99 power factor
- EN61000-3-2 harmonic content
- Universal input: 85 – 264VAC
- Short circuit protection
85 – 26467594%- Three-phase input
- 170 – 530VAC (L – L)
- 47 – 840Hz
- Chassis-mount or PCB-mount form factor
170 – 530-98,7%
Product overview DC-DC
Image
Description
Datasheet
Input
Output
Efficiency
- Up to 1300W, 46.4A continuous
- Up to 96% peak efficiency
- Up to 1244W/in3 power density
- OV, OC, UV, short circuit & thermal protection
9 – 420V3.3, 5, 12, 13.8, 15, 24, 28, 36, 48V96%- Simple to use
- High density
- Rich feature set
48V (36 – 75V) 48V (41 – 57V) 28V (16 – 50V) 24V (18 – 36V)3.3, 5, 12, 15, 18VUp to 89%- High density
- Wide VIN optimized for 48VOUT
- High efficiency
- Flexible
PRM: 36 – 75V VTM: 0 – 60VPRM: 5.0 – 55V VTM: 0 – 55VUp to 97%- Broad selection of input voltage, output voltage, and power levels
- High efficiency and power density in a brick package
- Simplified "brick" mounting and thermal management
- Robust packaging with operating temperature from –55 to 100°C
9 – 425V2 - 54V-- Up to 50W/in³
- Remote sense and current limit
- Overvoltage protection, thermal shutdown (VI-200 / VE-200)
- Wide-range output adjust
10 – 400VDC2 – 95VDC-
Image
Description
Datasheet
Input
Output Power
Efficiency
- High efficiency of up to 98%
- High power density of up to 2,735W/in3
- Parallel capability for higher power arrays
- Thermally-adept VIA housing
36.0 - 800.0V2.4 – 55.0V98%- High density
- Wide VIN optimized for 48VOUT
- High efficiency
- Flexible
0 – 60V0 – 55VUp to 96%
Image
Description
Datasheet
Input
Output
Power
- Wide input range 40 – 60VDC
- PMBus® compatible telemetry
- Parallel-capable up to four units
- Industrial Systems
54V12.2V750W- Up to 135A
- High-frequency Sine Amplitude Converter™
- ~1MHz switching frequency
- Non-isolated, voltage transformer
38 – 60V38 – 50V240W- High density
- Wide VIN optimized for 48VOUT
- High efficiency
- Flexible
48V (36 – 75V)48V (5 – 55V)Up to 600W- Wide operating range
- Simple to use; fast development time
- High efficiency
- Flexible and rich feature set
up to 12VIN nominal (8 to 18VIN)2.2 to 16V-- Wide operating range
- Simple to use; fast development time
- High efficiency
- Flexible and rich feature set
8 – 60V10 – 54VUp to 150W
Image
Description
Datasheet
Input
Output Power
Efficiency
- High efficiency >98%
- High power density of up to 3,600W/in3
- Parallel operation for multi‑kW arrays
- Bidirectional capability
36 – 60V7.2 – 15.3VOver 98%
Image
Description
Datasheet
Input
Current
Package
- Provides conducted common-mode (CM) and differential-mode (DM) attenuation from 150kHz to 30MHz (CISPR22 range)
- Optimized for applications that require EN55022 Class B limits
- 12, 24 & 48V nominal input voltages
- Saves up to 50% board space vs. standard filters
12, 24 and 48V7 or 14A25 x 12.4 x 4.5 mm , 25 x 25 x 4.5 mm- EMI filtering for Telecom and Railway applications
- Inrush current limiting
- Transient protection
- Low profile
max.15410 or 20A57,9 x 55,9 x 12,7mm- High surge withstand
- Input polarity protection
- Logic disable
- Expansion output for arrays (up to 800W)
24, 48 and 300VDC-57,9 x 61,0 x 12,7 mm- Reduces power supply output ripple to less than 10mVP-P
- Greater than 30dB PARD attenuation from 1 to 500kHz
- Greater than 99% efficient
- Improves transient response of DC-DC converters
3 – 30VDC / 0.3 – 5.5VDC10A / 20 A25 x 25 x 4.5 mm- Reduces output ripple to <3mVP-P (VI-200)
- Compatible with any VI-200 / VI-J00 based product with a 5 – 50VDC output
- No adjustments required
- Converter sense, trim, overvoltage and overcurrent retained
5 - 50VDC10A / 20 A / 30 A57,9 x 61,0 x 12,7 mm
Product overview MIL-COTS Power
Image
Description
Datasheet
Input
Output Power
Package
- Compatible with Vicor MI‑x7x family of modules
- Inrush limiting
- MIL‑STD‑461D/E CE102 compliance for conducted emissions
- MIL‑STD‑704A compliance for input transients
115VAC250W57,9 x 61,0 x 12,7mm
Image
Description
Datasheet
Input
Outputs
Power
- Up to 1300W, 46.4A continuous
- Up to 96% peak efficiency
- Up to 1,032W/in3 power density
- OV, OC, UV, short circuit and thermal protection
270V (160 – 420) 30V (9 – 50) 28V (16 – 50)3.3, 5, 12, 15, 24, 28, 48V500W - up to 1300W- Power density up to 312W/in3
- 1.3MHz switching frequency
- 95% efficiency
- ZVS buck-boost regulation
PRM28: 14 – 50V PRM48: 38 – 55V VTM: 26 – 50VPRM28: 26 – 50V PRM48: 20 – 55V VTM: 1.08 – 50VPRM: Up to 500W VTM: Up to 80A- Low‑noise zero‑current switching and zero‑voltage switching technology
- Output voltage adjusts from 10 to 110%
- Input undervoltage lockout
- Output overvoltage protection
24V (18 – 36V) - 375V (250 – 425V)2 – 54VDCUp to 600W- Remote sense
- Current limit
- OVP and thermal shut down
- Power boosters for higher power outputs
28VDC - 270VDC2 – 48VDCMI-200: Up to 100W MI-J00: Up to 50W- MIL-STD-704E/F compliant
- High efficiency up to >97.9%
- Power density >2,342 W/in3, at 36.58W/gram
- Can be paralleled to create multi-kW arrays
200 – 400VDC / 400 – 700VDC / 500 – 800VDC-Up to 35A- Wide operating range
- Simple to use; fast development time
- High efficiency
- Flexible and rich feature set
24VIN nominal (8 to 42VIN)2.2 to 6.5VUp to 22A- Wide operating range
- Simple to use; fast development time
- High efficiency
- Flexible and rich feature set
8 – 60V10 – 50VUp to 141.6W continuous
Image
Description
Datasheet
Input
Output Power
Output Voltage Config.
- Scalable OpenVPX compliant form-factor
- Overcurrent, overvoltage & overtemperature protections
- Military standard compliance to MIL‑STD 704F, 461F, 810G, 1275D
- No electrolytic capacitors
28/ 270600/ 1000Parallelable
Image
Description
Datasheet
Input
Current
Package
- Various transient compliance
- MIL‑STD‑461 EMI compliance
- Inrush current limiting
- Low‑profile mounting option
160 – 420 / 16 – 504 or 2284.04 x 35.93 x 10.57 mm / 44.6 x 35.5 x 9.2 mm- Provides conducted common-mode (CM) and differential-mode (DM) attenuation from 150kHz to 30MHz (CISPR22 range)
- Optimized for applications that require EN55022 Class B limits
- 12, 24 & 48V nominal input voltages
- Saves up to 50% board space vs. standard filters
05 – 50 / 10 – 40/ 30 – 80/ 36 – 76/ 05 – 50/ 30 – 807 or 1425 x 12.4 x 4.5 mm / 25 x 12.4 x 4.5 mm- Miscellaneous temporary compliance
- MIL-STD-461 EMI Compliance
- Inrush current limitation
- Low profile mounting option
10 – 36 / 14 – 50 / 14 – 36 / 180 – 3753, 10, 18, 20 or 25119,4 x 92,0 x 20,6 mm / 57,9 x 55,9 x 12,7 mm- MIL-STD-461C/D/E EMI compliance
- MIL‑STD‑704A-F, MIL‑STD‑1275A/B/D and DO‑160E compliance for transientsv
- MIL‑STD‑810 environment compliance
28 / 270-57,9 x 61,0 x 12,7mm- Reduces output PARD to <10mVP-P
- Full attenuation up to 20A load
- Compatible with all MI-series units from 5 to 50VDC output
5.0 - 50-57,9 x 61,0 x 12,7mm