PCS-CAN Interface

Interface between CANopen Bus System and Power Supply

Features

    • Voltage and current programming and monitoring
    • Node address setting selectable
    • Read back of power supply status signals
    • 600 V galvanic isolation
    • Factory installed

Functionalities

    • SYNC Object
    • Emergency Object
    • Node Guarding
    • Heartbeat
    • Expedited and Nonexpedited SDO transfer
    • Node address range 1 – 127

Specifications

Programming and monitoring resolution 14 bit
Communication speed up to 1 Mbit/s
Full scale accuracy < 0.1%

Dimensions and Weight

Width = 86 mm
Height = 89 mm
Depth = 119 mm
Weight = 0.7 kg

Downloads

Downloads Document format Size
Data sheet CANopen PDF (Acrobat Reader) 129.6 KB
Software CANopen Software 1.7 KB
Software CANopen Software 3.1 MB