600S Series

600 W Industrial, Prepared for N+1 fault tolerant (redundant) System

Features

    • Very high reliability, designed for long life at full power
    • EMC surpasses CE requirements: low emission & high immunity
    • Excellent dynamic response to load changes
    • Protected against all overload and short circuit conditions
    • Very low output ripple and spikes

Functionalities

    • Redundant parallel operation with undervoltage alarm contact
    • Screwdriver adjustable or analog programmable
    • Parallel and series operation
    • Convection cooling
    • 19” rack mounting or wall mounting
    • Remote sensing

Specifications

Single phase input 198-264 Vac (48-62 Hz)
99-132 Vac (48-62 Hz)
Active Power Factor Correction (PFC) up to 0.76 (at 100% load)
Efficiency up to 89% (at full load)
Output ripple and spikes from 7 mVrms / 20 mVpp
Regulation from 10 mV (0-100% load step)
Recovery time from 300 μs (50-100% load step)
Stability 30.10-5
MTBF up to 1.000.000 hrs
Operating ambient temperature -20 to +50 °C, derate current linearly to 20% at 75 °C

Standards

Power supply standard EN 61204-3
Generic Emission EN 61000-6-3 (EN 55022B)
Generic Immunity EN 61000-6-2
Safety EN 60950 / EN 61010
Insulation input / output 3750 Vrms
Enclosure IP20

Dimensions and Weight

Width = 433 mm
Height = 88 mm
Depth = 385 mm
Weight = 11 kg

Available units

Partnumber Voltage range Current range
600 S 24 12 – 15 V
24 V
30 V
30 A
25 A
20 A

Downloads

Downloads Document format Size
Data sheet 600S-Series PDF (Acrobat Reader) 261.6 KB