240S Series

240 W Industrial, Prepared for N+1 fault tolerant (redundant) Systems

Features

    • Excellent dynamic response to load changes
    • Very high reliability, designed for long life at full power
    • EMC surpasses CE requirements: low emission & high immunity
    • Protected against all overload and short circuit conditions
    • Very low output ripple and spikes

Functionalities

    • Redundant parallel operation with undervoltage alarm contact
    • Screwdriver adjustable or analog programmable
    • Parallel and series operation
    • Euro rack mounting or wall mounting
    • Convection cooling
    • Bench operation with bench adapter (optional)
    • Remote sensing

Specifications

Single phase input 195-265 Vac (48-62 Hz)
100-132 Vac (48-62 Hz)
Efficiency up to 88% (at full load)
Output ripple and spikes from 5 mVrms / 15 mVpp
Regulation from 10 mV (0-100% load step, external sensing)
Recovery time from 200 μs (50-100% load step)
Stability 30.10-5
MTBF 1.000.000 hrs
Operating ambient temperature -10 to +50 °C, derate current linearly to 20% at 80 °C

Standards

Power supply standard EN 61204-3
Generic Emission EN 61000-6-3 (EN 55022B)
Generic Immunity EN 61000-6-2
Safety EN 60950 / EN 61010
Insulation input / output 3750 Vrms
Enclosure IP20

Dimensions and Weight

Width = 71 mm
Height = 240 mm
Depth = 156 mm
Weight = 2 kg

Available units

Partnumber Voltage range Current range
240 S 24 12 – 15 V
       24 V
       30 V
12 A
10 A
8 A

Downloads

Downloads Document format Size
Data sheet 240S-Series PDF (Acrobat Reader) 203.6 KB